Zorak carries four main cooling chambers and two independent crew cooling chambers. Separate hull bays hold the radiator panels. The Qi fleet and facilities share the closed coolant loops, heat exchangers and fault controls. Space radiators emit heat to space. Earth dry coolers transfer it to outdoor air.
Zorak main-loop cooling rating
R4 adds 2,000 m² of two-sided emitting area across the four main
sectors. Each sector now provides 13,000 m², for a total of 52,000 m². The model retains
a 600 K radiator temperature and keeps 10% of available capacity in reserve.
Configuration
Absorbed heat (W/m²)
Available rejection (MW)
Dispatch after reserve (MW)
R3 · One sector out
100
207.07
186.36
R4 · All four sectors
100
287.14
258.42
R4 · One sector out
100
215.35
193.82
R4 · One sector out, warmer exposure
180
212.23
191.01
At 213.19 MW of fusion output, 10 MW of KETS diversion with full plasma heat
replacement gives the highest shared-loop load in the steady-state study at 189.98 MW.
R4 has 3.83 MW of dispatch headroom with one sector out and
1.03 MW under the warmer exposure.
In the warmer fault preset, one healthy crew train has 1.24 MW of rejection
capacity for 1.33 MW of crew heat.
The fault model holds propulsion in that case.
The rating assumes full two-sided deployment of each credited sector and the stated view to space.
Verify panel exposure, coolant flow and heat exchanger capacity before using it as an operating limit.
The layout uses Zorak’s approximately 680 × 168 × 126 m reference hull. The dimensions below reserve space for equipment and service access. They are preliminary packaging allowances for the next hull layout.
Radiator deployment plan
Main machinery
Crew machinery
Stowage bay
The 24 folded wings sit in six separate hull bays. The stowed panels receive zero heat-rejection credit in the study.
Compartment
Count
Per compartment (L × W × H)
Contents
Main cooling chamber
4
28 × 16 × 8 m 3,584 m³
Pumps, isolated exchanger, branch manifolds and valves, service access and an interface to the main thermal reserve.
Crew cooling chamber
2
12 × 8 × 5 m 480 m³
One independent crew train per chamber with pumps, chiller, heat exchanger, isolation valves and access to a protected feeder and battery.
Main radiator stowage bay
4
114 × 16 × 4 m 7,296 m³
Five folded wings per bay. Each wing has five hinged 20 × 13 m radiator leaves.
Crew radiator stowage bay
2
48 × 16 × 4 m 3,072 m³
Two folded wings per bay. Crew A and B use separate hull openings, coolant lines and deployment power.
A main leaf measures 20 × 13 m. Five leaves unfold to 65 m from the hinge.
With both faces exposed, each main wing provides 2,600 m² and five wings give a sector 13,000 m².
The crew wings use 20 × 12.5 m leaves and provide 5,000 m² per train. All 24 wings provide
62,000 m² across 120 leaves. Machinery chambers reserve 15,296 m³ in total.
Panel bays reserve another 35,328 m³. Reserve tanks, access and pipe runs need separate allowances.
The port and starboard bays sit at 104–218 m, 316–364 m and 456–570 m from the nose.
A 13 m folded main leaf leaves 3 m of the 16 m bay depth for clearances and hinges.
Each fold stack reserves 0.45 m of pitch per leaf, or 2.25 m for five leaves.
The bay allows 2 m between stacks and 3 m at each longitudinal end. With a 6 m hinge offset
beyond each side of the hull, the unfolded main wings span 310 m. Hinges, hot-loop materials,
coolant swivel joints and the swept envelope still need detailed design.
Before stowing, reduce heat input, divert residual heat to a verified path, and isolate the affected panels. During deployment, prove wing position, latch, coolant flow and an open view to space before SERAT credits capacity. With only one face available across a crew train, modeled capacity falls to about 0.82 MW under the same per-face conditions. The assumed essential load on local reserve is 1.46 MW, so SERAT needs the other train or a verified contingency.
Zorak radiator-sector loss
Cooling R4 simulation for a fault during sustained thrust.
DERATEDThe crew loop has cooling margin. The remaining main sectors support a lower thrust setting.
KETS heat load at the selected radiator setting
The KETS study holds fusion output at 213.19 MW with its original
crew and electrical loads. Change the number of main sectors out or the absorbed panel heat above to see what fits.
Selected main-loop dispatch limit
Fixed-power case
Heat load (MW)
Dispatch headroom (MW)
KETS bypassed
186.36
+7.45
5 MW · Surplus particles
185.62
+8.20
5 MW · Plasma heat replaced
188.17
+5.64
10 MW · Plasma heat replaced
189.98
+3.83
A negative value calls for a lower heat load. The fault model above checks crew cooling, telemetry
and reserve separately. Review the full KETS comparison
Cooling architecture
Two independent crew trains
Cabin and air handlers→Sealed exchanger and chiller→Crew radiator↺
Train A and Train B each reach essential occupied zones through independent heat pickups. Each has its own pumps, refrigeration, sealed fluid circuits, valves, radiator and protected feeder with a local battery. Separate routes and bulkhead penetrations reduce the chance that one leak or feeder fault disables both trains.
Allocate 5,000 m² of additional emitting area per train at 315 K for the screening case. The assumed cabin duty is 0.95 MW of sensible and latent heat, of which 0.75 MW comes from powered equipment. The chiller draws 0.38 MW at the assumed coefficient of performance of 2.5. One healthy train can reject 1.64 MW in the default environment. Allow 1.46 MW of heat rejection and 1.26 MW of electrical supply while the train runs on local reserve. Provide 0.70 MWh usable reserve per train.
Four isolatable main sectors
Fusion, KETS and drive heat→SERAT transfer loop→Main radiator sectors↺
The four main sectors provide 52,000 m² total effective emitting area. Account for
KETS converter and electrical losses in the main heat ledger. The phase-change reserve takes surplus heat
during a rollback. The fault case assumes 2.0 GJ is available and 60 MW can be transferred to it.
Keep the Integrated Hull Water Matrix behind a dedicated exchanger. The passive shielding function depends on retained water and coverage. Track both during heat exchange and isolate the water side if either falls outside its operating limits. The fault model uses the main phase-change reserve for its heat-storage credit.
Fault response and restoration
Local protection isolates a leaking or unpowered branch. The surviving crew train takes the essential cabin duty. The crew feeder has priority over flexible loads.
SERAT calculates remaining cooling and reserve from verified flow, supply and return temperatures, bank position, electrical power, and available storage. It recommends a coordinated reduction in fusion and drive output when the main loop loses capacity. NEXUS supervises and records the event.
KETS starts in bypass. A recovery request needs a measured net electrical gain and adequate main-loop cooling. On a cooling fault, SERAT checks the bypass heat load against the remaining capacity and lowers the fusion and drive request when required.
When essential capacity falls short or telemetry expires, SERAT reports HOLD. Independent local protection and AXIOM govern physical isolation and the veto. The restart check requires verified flow, leak isolation, stable temperatures and adequate reserve. ZSA owns qualification and release.
Heat rejection limits the power available for the Qi Fleet propulsion cycle. The fleet designs use isolated machinery spaces and exterior radiator branches, with life-support cooling separate from propulsion and mission loads. The dimensions are initial equipment allowances. Actual heat loads and available hull space set the final bank and chamber sizes.
Vessels
Preliminary machinery spaces (L × W × H)
Cooling integration
Zorak
4 main at 28 × 16 × 8 m 2 crew at 12 × 8 × 5 m
Four isolated main sectors for fusion, KETS and the drives. Each of the two crew trains has a dedicated radiator bank and a local power reserve. See the R4 ratings
Derko, Herko and Sorko
4 main at 22 × 12 × 7 m 2 crew at 10 × 7 × 4 m
Run docked-craft cooling through a metered, isolated exchanger. Count occupied berths in the essential cooling budget and verify deployment clearances with the hangars occupied.
Anorak and Fronak
4 main at 18 × 10 × 6 m 2 crew at 8 × 6 × 4 m
Feed labs and optional payloads from isolatable branches. Keep essential cabin cooling available during science-load shedding. Route the machinery around the CMC and survey apertures.
Centri and Ranok
4 main at 18 × 10 × 6 m 2 crew at 8 × 6 × 4 m
Use the research-vessel arrangement as a packaging basis. On Centri, check the radiator sweep with the Norak collar and approach corridor. On Ranok, verify the protected refuge load and the smaller available hull volume.
Norak
4 main at 5 × 3 × 3 m 2 crew at 5 × 4 × 3 m
Split the existing 8,200 m² main orbital study area into four 2,050 m² banks. Three banks yield about 34.0 MW gross and 30.6 MW for dispatch at the Zorak screening conditions. The 35.1 MW full-thrust heat case requires derating after one bank loss. Verify a timed heat reserve and essential cooling while panels are stowed for entry and landing.
Crewed interceptors and space shuttles
Compact equipment racks sized by craft and crew duty
Use a closed propulsion loop and an isolated crew loop. Size an independent reserve cooling path for the actual return or docking time. Credit host cooling only after the docking exchanger confirms capacity.
The fleet’s archived full-output heat values remain reference cases. Each ship needs a measured heat ledger, a validated bank-loss operating limit, and a cooling plan for stowed, docked and shield-active conditions. Zorak’s assumed 1.46 MW crew duty and panel count apply to the Zorak study.
Facility installations
The shared sequence is heat collection, isolated heat exchange, useful heat delivery when a customer can take it, then rejection of the remaining heat. Critical loads have a protected path and an independently verified shutdown heat sink. SERAT checks the available capacity when a heat customer, fan, pump or radiator bank drops out.
Facility
Study configuration
Single failure case
Earth Research Facility
Four outdoor closed-loop dry cooler groups at a target of 4 MW each, with a preliminary 12 × 8 × 5 m machinery allowance per group. Use sectionalized headers and independent fans and feeders. Screen at 30°C outdoor air and 50/40°C secondary coolant.
Three groups give 12 MW. Dispatch at 10.8 MW with 10% capacity held in reserve. That leaves 0.47 MW above the 10.33 MW working heat balance with useful heat demand unavailable. Vendor curves and seasonal conditions set actual duty.
Earth Fusion Power Facility and SERAT Energy Island
Evaluate four 100 MW dry groups for compatible secondary heat loads, with an initial 28 × 16 × 8 m machinery allowance per group. Maintain a separately sized main condenser heat sink and a dedicated shutdown heat path. Compare dry-first hybrid and all-dry performance against site weather and turbine backpressure.
Three groups give 300 MW before reserve, or 270 MW for dispatch. If the full 3,300 MW working heat balance must be rejected, about 3,030 MW still needs another heat path at this screening point. Recalculate the balance if electrical output changes.
CORAC lunar research outpost
Use three fixed 300 m² emitting banks on the hot loop, each with a preliminary 6 × 4 × 3 m machinery space. Screen at 360 K, emissivity 0.85, effective cold-sky view 0.80 and absorbed heat of 200 W/m². Route refuge loads through protected heat exchange with local backup.
Two banks yield about 269 kW before reserve, or 242 kW for dispatch. Compare with 140 kW of power-block heat and up to 60 kW more if all generated electricity ends as local heat. Size the refuge loop from its own temperature and outage budget.
For the research facility, a 4 MW group needs about 420 m³/s of air with an assumed 8°C rise and air density of 1.18 kg/m³. Use fan and pump curves, liquid return limits, hot-air recirculation, wind, icing and cold start to size the outdoor coil field. Include additional fan and pump heat and the loss of net export when updating the facility heat balance. For CORAC, verify the radiator’s view of the sky, solar and terrain heating, dust and night-time freeze protection at the selected site.
Verification before hardware release
Measurements that set the design
Meter the hottest essential occupied zone and the life-support equipment under the maximum crew and berth condition. Log cabin sensible and latent heat, coil temperatures, chiller lift and electrical draw.
Measure each train’s capacity with the other isolated. Include reserve losses, pump start and switchover, coolant return temperature, humidity control, leaks, and battery endurance.
Use a heater-driven two-train demonstrator for transfer and control testing. At 1:1,000 thermal scale, apply a 950 W equivalent cabin load, exercise transfer to one train and local reserve, and verify 1.46 kW of heat rejection for 30 minutes at the simulated sink condition. Record the temperature rise during switchover. Use thermal-vacuum testing for panel rejection and an installation model for Sun, planet, hull, docking and shield-state effects.
Fault tests and release evidence
Close the heat balance with one main sector out. Measure source rollback latency, buffer charging power and stored energy. Demonstrate stable fusion and drive output at the reduced power point, or determine the required source and radiator redesign.
Exercise one crew train out, power transfer to local reserve, stuck isolation valve, stale telemetry and a second fault during recovery. Verify temperature and humidity limits and the independent trip response.
Measure post-trip and shutdown heat. Define a verified heat-removal path for that residual load. Check emitter deployment, hinge and line failures, loop hydraulics, physical separation and hull fit before accepting operating limits.
Run the Earth research facility case with zero customer heat demand and one dry group unavailable. Verify return temperature, net auxiliary draw and reserve at the selected design weather. Run CORAC’s warm terrain and one-bank outage together.
Heat balance and design basis
Operating scale. Cooling R4 provides about 0.215 GW of gross main-loop rejection
with three sectors available at 600 K. The archived 45 GW jet-power study would leave about 321.7 GW of onboard heat,
which exceeds this cooling envelope. The R4 bypass fault model runs near 222 MW of fusion output after derating.
The KETS comparison uses a fixed 213.19 MW so the original and revised ratings can be compared at the same heat loads.
Radiators. The model calculates available heat rejection as area × max(0, εσT4 × 0.90 − absorbed heat per m²). It uses emissivity 0.85 and the Stefan–Boltzmann constant 5.670374419 × 10−8 W/m²/K4. The effective view factor of 0.90 and the default absorbed load of 100 W/m² are selected study inputs. Areas count emitting surfaces. The calculation assumes the pumps and exchangers can deliver the resulting heat rates. R1 reported a simulated 1,127 MW peak with one sector isolated and an emitter reaching 894.4 K. This revision uses the working values’ 600 K screening point.
Crew cooling. Cabin heat equals crew equipment electrical draw plus the other sensible and latent load. The chiller adds cabin heat divided by its coefficient of performance to electrical demand. Crew panels reject cabin heat and chiller input. The reserve case includes the full loss of the 90%-efficient backup power path as additional heat. The capacity check credits one healthy train so that either train can meet the essential load alone.
Main loop and thrust. Allow 90% of currently available main radiator capacity for steady dispatch. The bypass fault model uses the workbook’s 30% net electric conversion, up to 75/110 of remaining electrical power for propulsion, 60% electrical-to-jet efficiency and 50 km/s effective exhaust speed. It deducts crew electrical demand first and protects an assumed 15 MW minimum for other ship systems, including any required shield duty. Fusion output balances jet power, crew electrical power and main-loop heat. Other electrical loads dissipate into the main loop. Thrust is twice jet power divided by exhaust speed. The selected 200 MW minimum stable fusion output is a screening assumption for the operating core configuration.
Transient. The main sector drops out at time zero. The simulated source and drive hold their previous output for the detection and control delay, then reduce output together linearly. Peak stored heat is the integral of positive main-loop heat input above remaining radiator capacity. A case requires both enough usable energy space and enough instantaneous charging power. The model covers the controlled rollback from an initial radiator-limited state. Pump dynamics, temperature transients, minimum stable reactor and drive output, and shutdown heat require measured inputs.