EARTH & SPACE / PROGRAM ATLAS

Earth pollution report ·

Hydrogen, batteries and a cleaner Earth

Cleaner travel starts long before the wheels turn. Compare how vehicles are made, where their energy comes from, and what happens to their equipment after the last trip.

An electric bus, cyclist and pedestrians share a street near the waterfront in a Nordic town.
Concept illustration of electric transit, walking and cycling in a coastal town.

How clean is the same kilometre?

For most everyday driving, charge a right-sized battery vehicle directly with low-emissions electricity. That makes good use of each clean kilowatt-hour. Where public transport, a bicycle or a walk can serve the trip, fewer car kilometres can reduce both emissions and road wear.

Life-cycle climate estimates for EU medium cars and the ZENIT ZC-1 concept
Vehicle and energy source Bar chart scale g CO₂e/km
Fuel cellRenewable hydrogen50
Battery electricRenewable electricity52
Battery electricProjected EU electricity mix63
ZENIT ZC-1Renewable hydrogen · provisional74
Fuel cellNatural-gas hydrogen175
Gasoline carEU gasoline blend235
ZENIT ZC-1Unabated natural-gas hydrogen · provisional296

Lower is better. The five ICCT benchmarks model medium EU cars sold in 2025 and cover manufacture, energy supply, driving, maintenance and recycling. The projected EU grid case covers 2025–2044. The striped ZC-1 bars use published data from comparable vehicles. ICCT study, Figure ES1 · ZC-1 calculation and evidence gaps

With renewable hydrogen, the ZC-1 estimate is about 68% below the gasoline benchmark and 22 g CO₂e/km above the renewable-powered battery EV. Switching the ZC-1 to unabated natural-gas hydrogen raises its estimate above the gasoline benchmark.

The fuel is only as clean as its supply chain

Unabated natural-gas reforming produces hydrogen from methane and steam. The IEA benchmark is 10–12 kg CO₂e per kg of hydrogen. For unabated coal gasification it is 22–26 kg. Carbon capture can reduce plant emissions. Residual plant emissions and methane from the gas supply still count. IEA production benchmarks

Electrolysis runs on electricity and treated water

The same electrolyser can have very different emissions depending on where and when it draws power. Water treatment, cooling, delivery and hydrogen leakage also matter to the overall assessment. See how electrolysis works

50 g CO₂e/kWh electricity
2.75 kg CO₂e/kg H₂
400 g CO₂e/kWh electricity
22 kg CO₂e/kg H₂

Illustrative electricity contributions at the U.S. DOE benchmark of 55 kWh/kg H₂. These two figures cover electricity for electrolysis. A full comparison also counts equipment, water services outside the benchmark, delivery and leakage. DOE benchmark · CICERO on hydrogen leakage

What happens after the battery’s last trip?

A technician at a diagnostic station beside an open vehicle battery pack on an inspection lift.
Concept illustration of specialist inspection before reuse or material recovery.

A specialist take-back chain checks whether a pack can be repaired or safely used again. Packs that reach end of life can be separated into casing, foils and electrode-rich black mass. Heat-based and liquid-based refining recover selected materials. Direct recycling aims to preserve more of the electrode structure where chemistry and sorting allow. EPA recycling overview

EU targets measure two different things. The lithium-based battery recycling efficiency target rises from 65% by average weight at the end of 2025 to 70% at the end of 2030. The separate target for recovering the lithium itself is 50% at the end of 2027 and 80% at the end of 2031. These targets describe what facilities are required to achieve. EU Batteries Regulation, Annex XII

Hydrogen vehicles also leave equipment to recover, including tanks, stacks and electronics. Compare the whole product and the actual take-back route.

How ZENIT’s provisional scores were calculated

The ZC-1 model uses the ICCT’s 240,000 km lifetime, combustion-car manufacturing, recycling and maintenance estimates, and hydrogen supply factors of 1.2 and 13.6 kg CO₂e/kg H₂. Those fuel factors include compression and short-distance transport. The calculation adds a comparable hydrogen tank’s manufacturing footprint, uses 1.79 kg H₂/100 km from a simulated hydrogen-combustion car, and includes a small estimate for CO₂ from lubricant use. ICCT methods · Chalmers driving simulation · Paul Scherrer Institute tank inventory · Lubricant estimate

Climate · ZC-1
74 with renewable hydrogen · 296 with unabated gas hydrogen. Both are in g CO₂e/km. Replace the published proxies with measured ZC-1 fuel use, supplier data and the actual tank footprint. Tank retirement and any additional hydrogen leakage are still unquantified.
Air quality · ZC-1
Measurement needed. Measure on-road nitrogen oxides separately. Hydrogen combustion in air can produce NOₓ. DOE on combustion
Energy and heat · SERAT
Pilot proposed. Meter electricity saved and useful heat delivered against an existing facility baseline. Those results need their own units and do not assign a vehicle score.

See how the ZC-1 uses hydrogen · Explore ZENIT’s proposed Earth pilots

Three ways to cut more pollution now

  1. Make shorter, cleaner trips possible. Expand reliable public transport and safe cycling and walking routes. Electrify the journeys that still need a vehicle.
  2. Cut fuel use in buildings. Combine insulation, efficient heat pumps where suitable and useful recovered heat.
  3. Cut methane at the source. Fix leaks in oil and gas infrastructure, reduce food waste and improve gas control at landfills and wastewater plants.

IPCC transport assessment · IEA on heat pumps · UNEP on methane